If there is a response for the query in MibBrowser, it implies that the OID is implemented and the dial not appearing can be due to snmp timeout. This file is needed by Apache. There are quite a few things that you need to take note of when configuring modem-based sms alerts. Either always run your probe, and limit this behavior to the devices you care about, or add classifier(s) to discriminate between your device type and everything else that's out there, perhaps Source

To register all the WMI classes for the installed application. Add comment Created on Oct 18, 2010 12:43:04 PM by Torsten Lindner [Paessler Support] Permalink Votes:0 Your Vote: Up Down I am also having the same issue. Join them; it only takes a minute: Sign up emulator: WARNING: Unable to create sensors port: Connection refused up vote 0 down vote favorite I am using PhoneGap for android and Try the above 3 steps again.

A Connection Could Not Be Established Teamviewer

GSM Modems have a serial port and so you will need a standard serial cable. Click the Edit icon against a monitor. If not, can you describe how you are trying to "hook up" your SSHCommand probe? - Tim. Under the HKEY_LOCAL_MACHINE\SOFTWARE\Microsoft\Internet Explorer\Main\FeatureControl, create a new key named FEATURE_DISABLE_TELNET_PROTOCOL.

This isn't a regular *Unix device (running full OS), so SSH Classify doesn't work either. You can check the exact error for this when you run a vbs script from the command prompt as in cmd> cd [OpManagerHome]\conf\application\scripts\ cmd> cscript cpu.vbs [machinename] [domainname]\[username] [password] You can All sensors are showing active and running.One more thing, I have noticed afterupgrading from 5.0.4 to 5.1.0. Prtg Socket Error # 10061 Connection Refused The Firewall logs the traffic between the remote probe and the core server.

No go.The classifier doesn't work either and no OID information will provide the Supplier Serial # (this is a special case where the OEM is re-branding a Brocade device with their This document helps you troubleshoot the common problems that you might encounter when using OpManager. Die WMI Sensoren der beiden PCs lieferten nach dem Update auf 7.3.5 den oben beschriebenen WMI Fehler. https://kb.paessler.com/en/topic/14-what-can-i-do-about-connection-could-not-be-established-errors-on-my-wmi-sensors emulator: WARNING: Unable to create sensors port: Connection refused I am at my wits end.

Use at your own risk. Code Pe015 But atConfiguration >> Deployment >> Components >> AlienVault Center. Start the services if it is not started. This knowledgebase contains questions and answers about PRTG Network Monitor and network monitoring in general.

  • If so, can you override it?
  • Failed to establish connection with Web Server.
  • Click the 'Passwords' link to configure the correct username and password to the device.

Connection Could Not Be Established (800706ba: The Rpc Server Is Unavailable

For instance, WMI expects the user to have domain administrator's privilege. https://kb.paessler.com/en/topic/333-how-do-i-solve-a-connection-refused-socket-error-10061-in-enterprise-console Add comment Created on Nov 23, 2010 12:24:55 PM by Bruno Ruy (1) ●2 Permalink Votes:0 Your Vote: Up Down Hi, we also had this problem coming up and disappearing again. A Connection Could Not Be Established Teamviewer This knowledgebase contains questions and answers about PRTG Network Monitor and network monitoring in general. A Connection Could Not Be Established Teamviewer 11 If not, rediscover the device with correct SNMP parameters.

Oy!Hope this at least sparks some ideas for how to move forward, - Tim. System detects the port to which the modem/mobile is connected but OpManager fails to detect it: Ensure that the mobile or modem is supported in OpManager. However, when I do this, Port 161 is used and refused with this error: "Failed to connect TCP: Connection timed out: no further information:"Is there a way to trigger an SSHCommand Over 650 device templates are available out of the box. A Connection With The Server Could Not Be Established Ftp

To resolve the issue, remove the configured user name and password from "Passwords" link in the device snapshot page. 800706BA - The RPC server is unavailable. more hot questions question feed default about us tour help blog chat data legal privacy policy work here advertising info mobile contact us feedback Technology Life / Arts Culture / Recreation Just saw the log a few days ago. have a peek here This could be caused either by low memory availability or excessive memory consumption by WMI.

Stuck with schedulable class Interview question "How long will you stay with us?" Why is this 'Proof' by induction not valid? Wmi: Connection Could Not Be Established Note: Following are few error messages that you might encounter when trying to telnet/ssh a device. Open "Properties" dialog of the "ManageEngine OpManager" service Go to "Log On" tab In the "Log on as" option select "This Account".

The Apache Server may not have read and execute permissions to access the files under directory.

Telnet-based resource monitor is not showing any data If you have added a Telnet/SSH based Resource monitor, check if the UserName and Password specified are correct. It is possible that the device is down, or is too busy. From the menu, select File | Manage PRTG Server Connections. A Connection Could Not Be Established Partner Could Not Be Contacted At The Given Network Address Output the first position in your program for each input character Validate Random Die Tippers Two brothers, two watches Why credit card information mostly not stolen?

In both the PRTG Administration Tool and Enterprise Console, confirm the settings. Show 6 replies Timothy Broberg Jan 25, 2015 9:19 PM (in response to volteomatt) Re: Discovery: Trigger SSH Probe from SNMP Sensor I have done this exactly zero times, but perhaps Solution Check the SNMP configurations, rediscover the device and re-add the monitors. http://brrian.net/could-not/unable-to-create-directory-in-joomla.html If the SNMP agent is running on the router and you still do not see the blue star in the device icon, then check if the SNMP parameters are properly specified

cmd prompt from your Windows machine. It is possible that the desired application using the namespace is not installed properly. The particular OID (for which the performance monitor is configured) is not implemented in the device. You should get the list of drives available in the device.

i think the problem is in the SDK but i have also tried to un-install an reinstall but i have failed. You must make sure that a proper backup of all your data is available. © 1998 - 2016 Paessler AG Solutions • Imprint • Contact • Sitemap • Privacy Policy • After it finishes executing, run it once again to ensure all corrupt tables are repaired. After the system system detects the port to which the Modem\Mobile is connected, connect it to OpManager as follows: Start OpManager.

Erst nachdem ich die Credentials inklusive dem PC Namen in den Credentials der Device erfasst hatte, fingen die WMI Sensoren wieder an korrekt zu arbeiten. "Sammelcredentials" für mehrere nicht Domainmitglieder ohne To start with, it is important to understand how OpManager categorizes the devices into servers, routers, switches etc. Watson Product Search Search None of the above, continue with my search Issues with SiteProtector Console connecting to Application Server using NAT SiteProtector; application server; Nat Technote (troubleshooting) Problem(Abstract) Unable to Best Regards.

So my advice is to avoid defining credentials on group level for devices when entering no data in the "Domain or computer name" field, but in this case enter the credentials Unanswered Categories All Categories 5.8KGeneral 175 Getting Started 5 Intergalactic Hang Out 110 Security 101 38 AlienVault Labs 413 AlienVault Labs 413 AlienVault USM 4.6K Deployment Architecture 853 Installation 667 Updates Enabling RDP in IE7 Steps to enable RDP in IE7 in Windows installations: Goto Tools-> Internet options-> security. WF3 has worked from the local subnet's probe (MON1) all along and it's being addressed by IP from the probe MON1.

This a common error for all emulators for all versions. install probe remote Created on Sep 23, 2010 3:21:07 PM by Westermo (0) ●1 Permalink Best Answer Accepted Answer Votes:0 Your Vote: Up Down If you have problems with the setup You can add the following registry key to disable this feature of UAC. More discussions in Developer Community All PlacesDeveloper Community 6 Replies · Latest reply on Jan 28, 2015 2:03 PM by volteomatt Discovery: Trigger SSH Probe from SNMP Sensor volteomatt Jan 25,

Remove and re-add the monitors. Contact support with logs. I can see the traffic coming through the firewall but the RRTG server just does not process/acknowledge the remote probe request in any of it's log files. Now the changed entry will be as shown below: PROCESS com.adventnet.nms.poll.Collector ARGS POLL_OBJECTS_IN_MEMORY 25 POLL_JDBC true MAX_OIDS_IN_ONE_POLL 15 AUTHORIZATION true DATA_COLLECTION_QUERY_INTERVAL 120000 PASS_THRO_ALL_POLLING_OBJECTS true CLEAN_DATA_INTERVAL 999999 DATA_COLLECTION_SNMP_TIMEOUT 15 On the other